My cannon broke and pipe is stuck inside fitting!

Show us your pneumatic spud gun! Discuss pneumatic (compressed gas) powered potato guns and related accessories. Valve types, actuation, pipe, materials, fittings, compressors, safety, gas choices, and more.
pyrogeek
Specialist 4
Specialist 4
Posts: 457
Joined: Sat May 13, 2006 7:43 pm
Location: moline Illinios

Tue Jul 17, 2007 2:25 pm

replace all the fittings. They can't be that expensive, and you are just asking for trouble using DWV otherwise.
I'm weird, I know it, you don't need to tell me.
User avatar
spudbud101
Specialist
Specialist
Posts: 138
Joined: Wed Jun 28, 2006 11:35 pm
Location: Colorado
Contact:

Tue Jul 17, 2007 2:28 pm

Meh, I'll retire this cannon. I'm building another one anyway with a solenoid valve. Plus I ordered a block from noname.
Rawr.
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

Tue Jul 17, 2007 3:00 pm

spudbud101 wrote:Meh. Whatever. Its fine, I just want to fix it.
No its not, I just had some 260psi rated PVC explode next to me and two friends, no one was hurt but that was just pure luck it missed us all.
I've passed the solvent welding course so I know what im doing there and the gun has never been banged or dropped to weaken the fittings so I take it was just a fault in the fitting, though they aren't meant for air pressure.
User avatar
spudbud101
Specialist
Specialist
Posts: 138
Joined: Wed Jun 28, 2006 11:35 pm
Location: Colorado
Contact:

Tue Jul 17, 2007 3:38 pm

I've passed the course, too. I thought DWV fittings were okay to use.
Rawr.
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

Tue Jul 17, 2007 3:41 pm

Not in a pneumatic, where did you get that from?
User avatar
spudbud101
Specialist
Specialist
Posts: 138
Joined: Wed Jun 28, 2006 11:35 pm
Location: Colorado
Contact:

Tue Jul 17, 2007 4:03 pm

Some site that I can't find on Google. He said even though the fitting said DWV it should hold pressure because the PVC pipe said DWV. (All the PVC pipe I get says DWV but it is pressure rated).
Rawr.
anatov
Private 2
Private 2
Posts: 22
Joined: Thu Nov 16, 2006 6:24 pm

Tue Jul 17, 2007 4:27 pm

What's the solvent welding course?
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

Tue Jul 17, 2007 11:26 pm

It was stickied, next time use the search tool to find information instead of posting.

http://www.spudfiles.com/forums/solvent ... t3009.html
User avatar
frankrede
Sergeant Major 2
Sergeant Major 2
Posts: 3220
Joined: Thu Jul 20, 2006 9:47 pm
Has thanked: 1 time
Been thanked: 1 time

Wed Jul 18, 2007 1:15 am

spudbud101 wrote:Some site that I can't find on Google. He said even though the fitting said DWV it should hold pressure because the PVC pipe said DWV. (All the PVC pipe I get says DWV but it is pressure rated).
No, your pipe can have DWV on it, but it still must have a pressure rating too.
Fittings though must have nsf-pw on it, and have deep sockets.
Current project: Afghanistan deployment
Post Reply