co-axel diaphragm PROBLEM/material (pics)

A place for general potato gun questions and discussions.
theRIAA
Private
Private
Posts: 18
Joined: Fri May 19, 2006 5:26 pm

Sun May 21, 2006 1:03 am

summary of below: intertube for diaphragm? posible materials?

just finished building a nice gun out of 2" and 3/4" SCH 80 PVC. its a "co-axel diaphragm" and i have no expreience with it at all. it uses a blowgun to engage and scratener valve to fill. i made the diaphragm out of intertube (big ones you go down a snowy hill in, and i dont think its working. it wont engage at 3-20 psi (cant go higher, my valve leaks, ill fix it) it works at super low psi just fine. the intertube seems to be stretching out into the barrel. i screw the rubber up directly to the barrel (the 3/4" barrel is 1/3 way into the female threads on the 2" tank...this is ok right?)

if an intertube will not work, is there anything easy to get for diaphragm material (send me a link if you want, i already searched the forums). if intertube will work, tell me what im doing worng.

links to co-axel diaphram information sites would be appreciated!

some PICS to get u all exited
Image
diaphragm seen below oreo box... kindox looks like oreo
Image
HOLE where valve goes lol
Image
back is NOT dead space, damn HD didnt have any 2" ENDCAPS!?!?! filled it w/ water putty.... dead space is bad right?
Benny
Corporal 4
Corporal 4
Posts: 844
Joined: Wed Apr 19, 2006 8:21 pm
Location: Tasmania, Australia.

Sun May 21, 2006 2:31 am

its not dead space, its the pilot, but its good that you filled it in, because its less pilot to exaust by the blowgun,by my experiance innertubes dont seal very well.
McThrust
Private
Private
Posts: 15
Joined: Sat Mar 04, 2006 12:36 am

Sun May 21, 2006 5:34 am

im making a cannon nearly exact to this one (except with a 1/2 inch barrel) and i was wondering does it matter where you stick the blowgun? because this is the first co-axial that ive seen that has the blowgun on the side of the pipe rather than the direct back (or endcap).
theRIAA
Private
Private
Posts: 18
Joined: Fri May 19, 2006 5:26 pm

Sun May 21, 2006 3:00 pm

blowgun has to be BEHIND diaphragm


thanks, i think the air is just rushing past the endcap and not sealing, this could be beacuse the intertube just dosent seal or the intertube is actualy getting smaller in diameter, when it is "sucked" a little into the barel

what can i use?!?!
User avatar
sgort87
Corporal 5
Corporal 5
Posts: 994
Joined: Sun Sep 18, 2005 10:32 am
Location: Lockport, Illinois

Donating Members

Sun May 21, 2006 11:43 pm

Use a sheet of rubber sold at the hardware store. They sell them with gaskets and such so you can make your own custom gaskets and washers.
spudshot
Sergeant
Sergeant
Posts: 1036
Joined: Sun Oct 03, 2004 7:16 am

Mon May 22, 2006 5:32 am

you know thats conduit PVC right? made for underground wires, not pressure.
Image
McThrust
Private
Private
Posts: 15
Joined: Sat Mar 04, 2006 12:36 am

Mon May 22, 2006 7:32 am

is that a schrader adapter i see at the bottom of that trigger? if so that would be blocking and therefore stopping the air from being exhausted.
User avatar
)DEMON(
Sergeant 4
Sergeant 4
Posts: 1391
Joined: Sun Mar 12, 2006 1:22 pm
Location: Johannesburg South Africa

Mon May 22, 2006 9:34 am

i dont think that is a component for that gun
Forever dreaming...
User avatar
sgort87
Corporal 5
Corporal 5
Posts: 994
Joined: Sun Sep 18, 2005 10:32 am
Location: Lockport, Illinois

Donating Members

Mon May 22, 2006 10:21 am

2" conduit and under will hold up fine.
theRIAA
Private
Private
Posts: 18
Joined: Fri May 19, 2006 5:26 pm

Mon May 22, 2006 6:05 pm

spudshot wrote:you know thats conduit PVC right? made for underground wires, not pressure.
i always over-presure test my guns before i use them,
whats the diffrence in material of conduit and regular PVC?
it was heavy as hell
User avatar
sgort87
Corporal 5
Corporal 5
Posts: 994
Joined: Sun Sep 18, 2005 10:32 am
Location: Lockport, Illinois

Donating Members

Tue May 23, 2006 1:36 am

The density and plasticizing methods are different between them. Conduit PVC does not go through the same procedures as pressur-rated PVC. It is more brittle and could even be foamy like cellular core.
User avatar
noname
First Sergeant 4
First Sergeant 4
Posts: 2698
Joined: Mon Apr 10, 2006 9:19 pm
Location: Bay Area, CA

Sat Jun 10, 2006 10:01 am

Just go to a hardware store like gort said. Usually you can buy separate small sheets or sheets by the foot. At the Ace near where I live they have like 6 different types of rubber sheets in huge rolls.
User avatar
frogy
Corporal 2
Corporal 2
Posts: 603
Joined: Mon May 29, 2006 1:24 pm
Location: Ohio

Sat Jun 10, 2006 10:20 am

Look at the other Coaxials, they use a carriage bolt \ bolt with nuts washers and rubber.

N=Nut
W=Washer
R=Rubber


Bolt ==[N][W][R][W][N]==[N][W][R][W][N]===============[N][W][R][W][N]=
-FrOgY-

I wish people would stop needing a better signature!
Killjoy
Sergeant
Sergeant
Posts: 1052
Joined: Sun Nov 12, 2006 12:51 am
Location: New Mexico

Mon Dec 25, 2006 3:11 am

if you can't fin the rubber sheet, look for rubber caps for pipe, every homedepot and almost every Ace hardware ive been to has had them, they're thick rubber and all you have to do is cut it to fit. (and it should be thick enough not to get sucked into the barrel). they also cost about 3 bucks or less.
Post Reply