blow gun info?

A place for general potato gun questions and discussions.
unoriginalusername
Private
Private
Posts: 4
Joined: Fri May 06, 2005 11:51 am
Location: maryland

Sat May 28, 2005 9:59 am

g'day fellas

so i've stumbled upon the use of blow guns as triggers/vlaves in pneumatic cannons.

i have a few questions.

1. i've seen blowguns sticking out of solenoid valves, why's that?
2. can/do blowguns act as stand-alone valves? what psi can they handle?
3. is their any way to use a blowgun as a trigger/valve in the case of the cahmaber and breech as found on a solenoid sniper rifle, while still maintinaing the ergonomics of the stock design?

cheers
spudshot
Sergeant
Sergeant
Posts: 1036
Joined: Sun Oct 03, 2004 7:16 am

Sat May 28, 2005 11:24 am

1. its to make the solenoid valve open faster its called pneumatically modding the valve, and theres a tutorial for it on this site
2. they are a valve, but the flow is terrible for large guns, i use them on my bb guns though with good results.
3. you can use it for the trigger, just mod a solenoid valve and run hose from the modded port in your solenoid to the blowgun, and mount the blowgun where you want it for a trigger
Image
Aaron ?????
Private 4
Private 4
Posts: 99
Joined: Thu Mar 10, 2005 3:16 am
Location: australia

Mon May 30, 2005 3:59 am

yea i was just playing around with a blowgun and a peice of 3\16" id barrell (perfect for bbs) and discovered how good they are i could shoot a lead pellet straight through a coke can!!!! im thinking of a full auto rifle with a blow gun as the trigger
User avatar
iamthewalrus
Corporal
Corporal
Posts: 559
Joined: Mon Feb 28, 2005 9:28 pm
Location: Iowa (SO BORING!!)

Mon May 30, 2005 7:21 am

blowguns come in lots of different psi ratings, just check the back of the box and it should say, u will need at least a 125psi rated blowgun
i got connections with the modfia, watch who ur talkin to noob.


talk to me on AIM at iamthwalrus3
spudshot
Sergeant
Sergeant
Posts: 1036
Joined: Sun Oct 03, 2004 7:16 am

Mon May 30, 2005 8:46 am

some say dont use over 25 psi or some shit like that, all you need to do is take off the tapered nozzle of the blowgun, you can still have an input pressure of about 125 psi with no problems
Image
User avatar
iamthewalrus
Corporal
Corporal
Posts: 559
Joined: Mon Feb 28, 2005 9:28 pm
Location: Iowa (SO BORING!!)

Mon May 30, 2005 9:06 am

really?? wow, so if u get a blowgun that says only 25psi on it u can still use it to 125psi??
i got connections with the modfia, watch who ur talkin to noob.


talk to me on AIM at iamthwalrus3
User avatar
theexp
Specialist
Specialist
Posts: 157
Joined: Sun Oct 03, 2004 3:19 pm
Location: Chapel Hill NC
Contact:

Mon May 30, 2005 10:28 am

When i use ones that say use only 30 psi and under for over like 90 they start leaking after wards, and i have to take it apart, wipe everything clean and put it back together.
Post Reply