Sprinkler Valve leaking

Show us your pneumatic spud gun! Discuss pneumatic (compressed gas) powered potato guns and related accessories. Valve types, actuation, pipe, materials, fittings, compressors, safety, gas choices, and more.
Southside39
Recruit
Recruit
Posts: 1
Joined: Wed Aug 19, 2009 10:15 am

Wed Aug 19, 2009 10:29 am

I have a rainbird CP 100 Sprinkler valve and whenever I fill it it leaks out of the top where I drilled to put the blowgun in. It doesn't dump the pilot, but it loses pressure quickly. I am still able to shoot it if I use a compressor and shoot it right away before it loses all the pressure. I have tried jb-weld and epoxy on the blowgun to keep it from leaking but it still leaks. Any idea what could be wrong?
DinerKid
Private 4
Private 4
Posts: 67
Joined: Fri Aug 29, 2008 6:21 pm

Wed Aug 19, 2009 10:39 am

my guess would be that when you screwed in the blowgun or hose barb that the hole you drilled was too large and you didn't get a good seal. if you want to fix it you could get an adapter for the blowgun that makes the male connector larger by a little bit and the drill a slightly larger hole in the valve and screw in the blowgun with the adapter.
User avatar
jackssmirkingrevenge
Five Star General
Five Star General
Posts: 26189
Joined: Thu Mar 15, 2007 11:28 pm
Has thanked: 551 times
Been thanked: 328 times

Donating Members

Wed Aug 19, 2009 10:45 am

A photo would help a better assessment of the problem ;)
ralphd
Specialist
Specialist
Posts: 192
Joined: Mon Dec 17, 2007 8:07 pm
Location: Niles Ohio

Wed Aug 19, 2009 5:07 pm

There is a product called Leak Lock which works wonders. I use it on air conditioning systems. It's blue and available in a tube or jar at any fine hardware store near you.
Tcoz370
Private
Private
Posts: 18
Joined: Sun Jun 29, 2008 7:47 pm

Wed Aug 19, 2009 5:11 pm

teflon tape=solve all
User avatar
Hubb
First Sergeant 2
First Sergeant 2
Posts: 2390
Joined: Mon May 28, 2007 8:39 am
Location: South Georgia
Contact:

Wed Aug 19, 2009 5:14 pm

Is it leaking through the fitting or around it? Spray it with some soapy water to find out (look for the bubblies).

If it is leaking from around the fitting, just put a good epoxy around it. It will seal it, but make it non removable. If it is leaking through the fitting, then replace it.

Another thing to check is the drain plug. It should be a tiny screw found somewhere on top of the valve. You'd be surprised at the number of people who forget about this little doohicky. Just take out the screw and fill in the hole. Oh, and make sure you have filled the solenoid hole correctly.