i've used 1/4" brakeline with steel bbs and it was never accurate. i was hoping there is a place to buy brass pipe in a 4.5mm id.
- Gippeto
- First Sergeant 3
- Posts: 2504
- Joined: Sat Jan 19, 2008 10:14 am
- Location: Soon to be socialist shit hole.
- Has thanked: 2 times
- Been thanked: 17 times
Not enough information.wyz2285 wrote:Hi I´m making a new pcp rifle, and I´m planing using a stainless steel tube as chamber, 0.75mm wall. Is it safe to use 1000 psi with it?
What "kind" of stainless? ie 304, 316, 440, etc. You need to be able to determine the yield strength of the material...can't find that if you don't know what it is.
What's the outer diameter?
How are you going to secure the ends?
"It could be that the purpose of your life is to serve as a warning to others" – unknown
Liberalism is a mental disorder, reality is it's cure.
Liberalism is a mental disorder, reality is it's cure.
- Lockednloaded
- Staff Sergeant
- Posts: 1566
- Joined: Thu Sep 03, 2009 9:38 pm
- Location: Texas, USA
- Been thanked: 7 times
Would it be ok to tap a 1/8" thread through double layered 3/4" copper (type M tubing JFC'd into a 3/4" cap) if I plan to use up to 500 psi?
I love lamp
- mark.f
- Sergeant Major 4
- Posts: 3638
- Joined: Sat May 06, 2006 11:18 am
- Location: The Big Steezy
- Has thanked: 58 times
- Been thanked: 59 times
- Contact:
Uh, JFC'd?
The total wall thickness of those two parts would be just about 1/16"... really not enough thread engagement IMO for a course 1/8" NPT thread.
The total wall thickness of those two parts would be just about 1/16"... really not enough thread engagement IMO for a course 1/8" NPT thread.
- Gun Freak
- Lieutenant 5
- Posts: 4971
- Joined: Mon Jan 25, 2010 4:38 pm
- Location: Florida
- Been thanked: 8 times
JFC= just for copper, a chemical bonding thing for copper. I wouldn't tap that small depth. That's only maybe 2 threads to engage.
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna" ■ M16 BBMG ■ Pengun ■ Hammer Valve Airsoft Sniper ■ High Pressure .22 Coax
Holy Shat!
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna" ■ M16 BBMG ■ Pengun ■ Hammer Valve Airsoft Sniper ■ High Pressure .22 Coax
Holy Shat!
- Lockednloaded
- Staff Sergeant
- Posts: 1566
- Joined: Thu Sep 03, 2009 9:38 pm
- Location: Texas, USA
- Been thanked: 7 times
JustForCopper glue, it supposed to hold like 600 psi. What if I reinforce it with some epoxy?
I love lamp
- Gun Freak
- Lieutenant 5
- Posts: 4971
- Joined: Mon Jan 25, 2010 4:38 pm
- Location: Florida
- Been thanked: 8 times
Surely there's another option? I wouldn't trust the epoxy reinforcement either.
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna" ■ M16 BBMG ■ Pengun ■ Hammer Valve Airsoft Sniper ■ High Pressure .22 Coax
Holy Shat!
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna" ■ M16 BBMG ■ Pengun ■ Hammer Valve Airsoft Sniper ■ High Pressure .22 Coax
Holy Shat!
- mark.f
- Sergeant Major 4
- Posts: 3638
- Joined: Sat May 06, 2006 11:18 am
- Location: The Big Steezy
- Has thanked: 58 times
- Been thanked: 59 times
- Contact:
I don't know if you can get to the inside, but I think it you threaded the fitting through and added a sliver of 1/8" coupling and some epoxy on the other side it would be alright.
- Lockednloaded
- Staff Sergeant
- Posts: 1566
- Joined: Thu Sep 03, 2009 9:38 pm
- Location: Texas, USA
- Been thanked: 7 times
I guess I could put it in the end of the cap so it'd be easier to reinforce
I love lamp
- Gippeto
- First Sergeant 3
- Posts: 2504
- Joined: Sat Jan 19, 2008 10:14 am
- Location: Soon to be socialist shit hole.
- Has thanked: 2 times
- Been thanked: 17 times
You can get reducer bushings that have thread in them....they're designed to sweat into copper fittings to attach such things as snifter (schrader) valves...look in the heating section where they have boiler system parts.
"It could be that the purpose of your life is to serve as a warning to others" – unknown
Liberalism is a mental disorder, reality is it's cure.
Liberalism is a mental disorder, reality is it's cure.
- jackssmirkingrevenge
- Five Star General
- Posts: 26203
- Joined: Thu Mar 15, 2007 11:28 pm
- Has thanked: 569 times
- Been thanked: 345 times
The problem is that steel BBs are 4.4mm ID...subterranean wrote:i've used 1/4" brakeline with steel bbs and it was never accurate. i was hoping there is a place to buy brass pipe in a 4.5mm id.
hectmarr wrote:You have to make many weapons, because this field is long and short life
Hey, I was wondering if there is any useful tutorials on the application of liquid epoxy. I have used two part modeling epoxy before but never liquid epoxy and was wondering if there are any particular brands or types I should be leaning towards purchasing.
Any help is really appreciated
Any help is really appreciated
Trying to be innovative.
- jackssmirkingrevenge
- Five Star General
- Posts: 26203
- Joined: Thu Mar 15, 2007 11:28 pm
- Has thanked: 569 times
- Been thanked: 345 times
look no further:sl33k wrote:Hey, I was wondering if there is any useful tutorials on the application of liquid epoxy.
http://www.spudfiles.com/forums/epoxy-c ... t8916.html
http://www.spudfiles.com/forums/making- ... t8919.html
hectmarr wrote:You have to make many weapons, because this field is long and short life
- wyz2285
- First Sergeant 2
- Posts: 2385
- Joined: Sat Mar 06, 2010 7:50 am
- Location: Porto, Portugal
- Has thanked: 1 time
- Been thanked: 3 times
- Contact:
I don´t know just normal stainless steel tubes used for water...What "kind" of stainless? ie 304, 316, 440, etc. You need to be able to determine the yield strength of the material...can't find that if you don't know what it is.
OD wound be 22mm