Problem with sprinkler valve
I have a slight problem with the sprinkler valve I bought from Amazon.com and use this tutorial.
http://www.spudfiles.com/forums/no-dril ... t2497.html
I've removed all the parts stated, all except for the spring, and I attached a 1/4" blow gun. Unfortunately the valve isn't working. I pump air into the reservoir and it just goes out the barrel. The only difference is that I attached a polyetheline tube from the valve to the blowgun to reduce direct stress on the connection and I used silicon oil on the diaphram to avoid chaffing.
The one concern I have is that I tested the valve before modding it. I blew into one end and air came out the other, then tried it the other way and the same thing. I'm wondering if the valve is defective.
Here's the cannon to give you an idea.
http://www.spudfiles.com/forums/no-dril ... t2497.html
I've removed all the parts stated, all except for the spring, and I attached a 1/4" blow gun. Unfortunately the valve isn't working. I pump air into the reservoir and it just goes out the barrel. The only difference is that I attached a polyetheline tube from the valve to the blowgun to reduce direct stress on the connection and I used silicon oil on the diaphram to avoid chaffing.
The one concern I have is that I tested the valve before modding it. I blew into one end and air came out the other, then tried it the other way and the same thing. I'm wondering if the valve is defective.
Here's the cannon to give you an idea.
- homedepotpro
- Specialist 4
- Posts: 443
- Joined: Sun Nov 26, 2006 1:00 am
is it leaking from above the diaphram
- TwitchTheAussie
- Corporal 5
- Posts: 980
- Joined: Tue Feb 06, 2007 3:23 am
Pull it apart and try again. I honestly cannot find fault with what youve done but you never know the spring might have got knocked out of place.
Raise your horns if you love metal.
CpTn_lAw
-spudgunning is like sex, once you've tasted, you can't wait til next time.
CpTn_lAw
- MrCrowley
- Moderator
- Posts: 10078
- Joined: Fri Jun 23, 2006 10:42 pm
- Location: Auckland, New Zealand
- Been thanked: 3 times
Read this sticky:
http://www.spudfiles.com/forums/sprinkl ... t8780.html
Also blowing into the valve wont seal the diaphragm. You need alot more pressure faster. Make sure your valve isn't backawards and what are you pumping your gun with?
http://www.spudfiles.com/forums/sprinkl ... t8780.html
Also blowing into the valve wont seal the diaphragm. You need alot more pressure faster. Make sure your valve isn't backawards and what are you pumping your gun with?
- Flying_Salt
- Corporal 3
- Posts: 779
- Joined: Mon Oct 09, 2006 4:57 pm
- Location: Texas
There's a pop in at the end on the right side of the picture.frankrede wrote:your cannon has a dwv reducer:(
how are you filling your chamber?
sgort87 wrote: I hereby present Flying_Salt with The one and only <a href="http://www.geocities.com/sgort87/ghetto">Ghetto Award!</a>
-
- Specialist 2
- Posts: 283
- Joined: Wed Jan 03, 2007 8:59 pm
That gun looks like a dwv deathhole to me. Is that pipe even rated?
-I'm filling up with a bike pump
-I don't think it's leaking above the diaphram or out the blow gun
-Diaphram has no punctures or lacerations
-The spring should be set in place
-I've tried reversing the valve
-Pipe is schedule 40 should be good enough. This one guy I met at the parts store uses sch 40 with no problem especially if i'm going to be launching beanbags.
-I don't think it's leaking above the diaphram or out the blow gun
-Diaphram has no punctures or lacerations
-The spring should be set in place
-I've tried reversing the valve
-Pipe is schedule 40 should be good enough. This one guy I met at the parts store uses sch 40 with no problem especially if i'm going to be launching beanbags.
Sch 40 is a thickness for pipe, not a pressure rating. If you haven't cemented the gun together yet, good. You need to get rid of that reducer. LGM, bike pumps work fine with sprinkler valves, I know from a 2 1/2 year experience.
The reducer on the pressure chamber is the problem. Is is a DWV (drain, waste, vent) fitting that isn't made to hold pressure. It has a very short socket depth and will blow out eventually. Cut it off and get a 3" coupler and a 3" x 1" reducing bushing.
- turbohacker
- Specialist 3
- Posts: 392
- Joined: Wed Dec 20, 2006 12:34 am
put a ball valve before the sprinkler valve and pupm it up, then relese the pressure with the ball valve. If that does not work than you know your valve is wrong.
<-- This is not a cat avatar
If it walks like a dog, sratches like a dog, and barks like a dog, than its probobly a...-TURTLE, it's a TURTLE!!! Cant you see?!!!
If it walks like a dog, sratches like a dog, and barks like a dog, than its probobly a...-TURTLE, it's a TURTLE!!! Cant you see?!!!
frankrede wrote:Great googlay mooglay!
Thats a beast!